The explosion-proof analysis cabin is used in production processes such as refining, chemical, metallurgy, pharmaceuticals, and light industry, providing a safe installation space and protection for various online gas analyzers and online water quality analyzers.
Cabin Size
Manufactured according to user needs, generally based on the external dimensions of the cabin.3000mm (Length)x3000mm (Width)x3000mm(Height)
The cabin is a non-standard product, and its size can be determined based on the number, type, complexity of the system, and maintenance space of the analyzers, with appropriate allowances. Due to long-distance transportation constraints, its external dimensions are generally as follows.:
Length:Outdoor Main Body2.5~6.5mConsidering the standard steel material specifications and the strength issues of hoisting and transportation structures, the length of a single analysis cabin should not exceed6.5m, if the length6.5m, a modular structure can be used, made in parts, and assembled on-site, or two analysis cabins can be used to achieve.).
Width:Outdoor Main Body2.5m, the maximum width should not exceed3.0m(Due to highway transportation width restrictions, the width should not exceed3.0m).
Height:Outdoor Main Body2.5~3.0m (Due to height restrictions when passing through overpasses and tunnels.)The indoor net height is2.2~2.8m
Cabin Structure and Material Requirements
(1)Frame, Base, and Roof
The frame, base, and roof of the analysis cabin are made of metal components, welded from section steel, and should have sufficient strength and rigidity to ensure that the analysis cabin does not deform under load, hoisting, translation, and transportation. The main frame of the base should use 12# 20#channel steel, with two10#~12#channel steel or I-beams used as supporting beams under the floor joists. The main frame, floor joists, and supporting beams should be welded together to ensure that the floor does not shake when maintenance personnel walk inside. The roof frame and main beams should use10#12#.Fugang, and in the width direction, use8# ~10#Meigang as the main beams and roof joist supports, all should be welded together to prevent twisting and deformation. The roof should have a certain slope, with a minimum slope of4%.It can be in an A-shaped or one-sided sloped structure, and flat roofs are not allowed to prevent rainwater accumulation.(2)Inner and Outer Wall and Ceiling PanelsThe outer panels should be made of steel plates, and a few types of panel assembly structures can be used to form the outer walls. When welding
Ttechnology can be used.
Product Details1.5mm2.0mmApplicable Scope:a. Hazardous locations for explosive gas mixtures: Zone 1, Zone 2b. Explosive gas mixtures: II A, II B, II C level locations.
c. Temperature group: T4
d. Indoor, outdoor
Product Features:
1. The main and auxiliary cabinet combination can be in left-right or up-down forms, with the main cabinet being a positive pressure sealed chamber, front and back opening doors, and an observation window on the front. The auxiliary cabinet mainly houses the positive pressure gas route control system.
2. It has automatic ventilation before startup, ventilation delay, automatic gas replenishment, and automatic control of the positive pressure range.
3. Simple and convenient operation, entering "positive pressure operation" status immediately after ventilation.
4. It has positive pressure protection (upper and lower limits), sound and light alarms, automatic power-off under critical lower limits of positive pressure, power-off when opening the door, emergency manual power-off, and other interlock protection functions.
5. Cable pressure ring type introduction device.
6. Various instruments, inverters, PLCs, soft starters, and computer control systems can be installed inside the product, allowing for local and remote control.
Model: Explosion-proof analysis cabin
Explosion-proof station room
Explosion-proof positive pressure cabin
Pressure-resistant, anti-corrosion, flame-retardant, explosion-proof
Explosion-proof type Indoor environment temperature: 5℃-45℃ Environmental humidity:--≤95%
Altitude:≤2000M
环境湿度;≤95%
海拔高度;≤2000M
Applicable to explosive gas locations;IIClass2area, withⅡA,ⅡB,ⅡClevel
temperature range;T1~T4
Ambient temperature:-20℃~40℃
Power supply:AC220﹢﹣10% 50Hz
Atmospheric pressure:50KPa~106KPa
No strong vibration
The indoor temperature of the analysis room should be based on the requirements of the installed analytical instruments,take heating or air conditioning measures
The inlet of the analysis room's exhaust duct should be in a non-hazardous area.
Scope of application;
The explosion-proof cabin is suitable for environments containing explosive hazardous gasesIIClass2area, withⅡA,ⅡB,ⅡClevel, with a temperature group ofT1~T4explosive environments.;Altitude not exceeding2000meters; at 25℃the relative humidity95%or below;Working environment temperature-20℃~+40℃between.
Reference standards;
The various indicators of the explosion-proof cabin are referenced from national standardsGB3836.1-2010"Explosive Environment Part1Equipment General Requirements":,"GB383"Explosive Environment Part2Equipment General Requirements":with explosion-proof enclosure"d"protected equipment"GB3836.5-2004,"5Equipment General Requirements""p""GB3836.13-2013"Explosive Environment Part13Equipment General Requirements":Repair, maintenance, restoration, and modification of equipment"GB3836.15-2000,"15Equipment General Requirements":Electrical installation in hazardous locations(excluding coal mines)"GB3836.17-2007"Electrical Equipment for Explosive Gas Environments Part17or building structure and use" design and manufacturing requirements.

Previous Page
Next Page
Previous Page
None
Next Page
Qualification & Certificates
Large Scale Exhibitions
Factory Shipment
FAQ
Where is your factory located?
Our factory address is: No. 15, Jiaqi Road, Xianlin Street, Yuhang District, Hangzhou, Zhejiang Province, China.
If I have a large order, will you have a discount?
Yes, we can provide different discounts according to your order quantity.
Are you a manufacturer, trading company or a third party?
We are a manufacturer and have established the company since 2010.
Can we visit your factory before placing an order?
Yes, very welcome, it is very helpful to establish a good business relationship.
Can we be your agent?
Yes, welcome to cooperate with us, we are now vigorously promoting it in the market, please contact our overseas manager for details.
What is your minimum order quantity?
First of all, please tell us which product you need. Such as model, application scenario, technical requirements, etc. Generally, our minimum order quantity has different standards according to different regions, you can contact our overseas manager for details.